NF Membrane

The NF series nanofiltration membrane elements produced by WSD have selective separation characteristics. They can remove almost all bacteria, viruses, microorganisms and macromolecular organic matter in water or solution, and have a high removal rate for antibiotics, insecticides, pesticides, heavy metals and most divalent and above ions, while retaining some beneficial nutrient minerals and small molecules such as sodium, potassium, calcium, magnesium, and metasilicic acid. They can be used for the preparation of direct drinking water, mineral water, and softened water, partial desalination and decolorization of wastewater with high salt concentration and organic concentration, and separation and purification of some inorganic salts, organic matter and other materials.
The operating pressure of the nanofiltration series products is extremely low, which can greatly save the operating cost of equipment or systems, and is widely used in drinking water, food and beverage, medicine, reclaimed water reuse, wastewater treatment and other industries.


■ Technical Parameters

Model

Effective Membrane Area ft² (m²)

Water Production GPD (m³/d)

Removal Rate (%)

Test Fluid

WSD-NF1-4040

85(7.9)

2200(8.3)

50-70

NaCl

1800(6.8)

>98

MgsO₄

WSD-NF1-8040

400(37.2)

11000(41.6)

50-70

NaCl

9000(34.0)

>98

MgsO₄

WSD-NF1-4040R

85(7.9)

2200(8.3)

>85

NaCl

1800(6.8)

>99

MgsO₄

WSD-NF1-8040R

400(37.2)

11000(41.6)

>85

NaCl

9000(34.0)

>99

MgSO₄

 

Test Conditions

Test Pressure

Test Solution

Test Temperature

pH

Recovery Rate

70PSI

500PPM NaCl

77°F(25℃)

7.5-8.0

15%

70PSI

2000PPM  MgSO₄

77°F(25℃)

6.5-7.0

15%

*The water output of a single element may fluctuate within the range of ±15%


Nanofiltration Membrane Operating Limit
Maximum operating pressure------------- 600psi (4.14MPa)
Maximum inlet flow rate------------- 17.0m³/h (8040), 3.6m³/h (4040)
Inlet temperature range------------- O-45C
Maximum inlet SDI 15 ------------- 5.0
Maximum residual chlorine concentration------------- 0.1mg/L
Inlet pH range during continuous operation------------- 3-10
Inlet pH range during chemical cleaning------------- 1-13
Maximum allowable pressure drop of a single membrane element------------- 15psi (0.1MPa)

 

Dimensions

Model

A(inch/mm)

B(inch/mm)

C(inch/mm)

D(inch/mm)

E(inch/mm)

4040

40''

1016mm

1.06''

27mm

0.75''

19mm

3.9''

99mm

37.87''

962mm

8040

40''

1016mm

------

------

7.9''

200mm

------

 

It is recommended to flush the membrane element for 24 hours before first use and drain the flushing water directly. For ease of installation, apply lubricant to all seals. Keep the element moist at all times after initial wetting. To prevent bacterial biogrowth when the system is shut down for a long time, it is recommended to immerse the membrane element in a preservative solution. Rinse off the preservative before use. The membrane has a certain resistance to short-term attack by chlorine (hypochlorite). Avoid long-term exposure to sunlight!

● Product performance may vary under different conditions. The information on this website is for reference only and is not intended to be used as a basis for performance guarantees in actual applications. WSD reserves the right to make changes. If required, clients may consult with our sales representatives about the latest information, of which no further notice will be given.